Heavy Duty Flush
The only flush available to dissolve burnt glycol.
![](https://cdn.shopify.com/s/files/1/0501/9566/0969/t/3/assets/c8c921133639e824a9bb0c611a5d3550.jpeg?v=1674858796)
![](https://cdn.shopify.com/s/files/1/0501/9566/0969/t/3/assets/4659c32a1949434c5c4ad3b785adef97.jpeg?v=1674857701)
![](https://cdn.shopify.com/s/files/1/0501/9566/0969/t/3/assets/e3c9b209988f7cf66fb91ad1803ce60a.jpeg?v=1674857700)
![](https://cdn.shopify.com/s/files/1/0501/9566/0969/t/3/assets/63e4323f3f6f440d3e88745a4e70e5c4.jpeg?v=1674857700)
![](https://cdn.shopify.com/s/files/1/0501/9566/0969/t/3/assets/85cda642d82accf096cc8dc5717b976d.png?v=1674857750)
![](https://cdn.shopify.com/s/files/1/0501/9566/0969/files/3008A80B-494D-4FF5-8D39-9244C0337EF8_480x480.jpg?v=1628529990)
ULTIMATE CHEMICALS HDF – HEAVY DUTY FLUSH PROCEDURES
STEP 1
- Record water pump pressure and all temps.
- Shutdown/Remove Surge Tank Cap.
- Drain coolant and dispose.
- Remove Surge/Day Tank Caps.
- Install 1” ball valve on each side of block underneath rail.
- Fill with HDF (Ready to Use) until overflow from Surge/Day Tank.
- Run Unit 168 hours to 336 hours.
STEP 2
- Shutdown/Remove Surge Tank Cap.
- Power wash Surge Tank with STH - Surge Tank Hose (while still hot and full). Let particles overflow. (15-20 min)
- Drain Flush via ball valve on each side of block underneath rail. (dispose)
- Fill with HDF (Ready to Use) until overflow from Surge/Day Tank.
- Run Unit 168 hours to 336 hours.
STEP 3
- Shutdown/Remove Surge Tank Cap.
- Power wash Surge Tank with STH - Surge Tank Hose (while still hot and full). Let particles overflow. (15-20 min)
- Drain Flush via ball valve on each side of block underneath rail. (dispose as you would old coolant)
- (Rust Removal Flush – If needed)
- Fill with RRF - Rust Removal Flush and run 2 hours at temp. Drain Flush and dispose.
- (Phosphate Removal Flush – If needed)
- Fill with PO4FIX - Phosphate Removal Flush and run 4 hours at temp. Drain Flush and dispose.
- Fill with deionized water until overflow from Surge/Day Tank.
- Run Unit until up to temperature and thermostats open.
- Continue to pump in deionized water until overflow at the top from Surge/Day Tank and ball valves on other side. (2 x volume) overflow until clean.
- Inspect water pump and replace thermostats.
- Drain Unit / Fill with New Coolant*
*(Best Practice) Do not leave or run with water only.
*(Fill with coolant mix and CRI – Corrosion Rust Inhibitor – recommended)